Features:
  • Microprocessor Design.
  • Quad Frequency Analysis.
  • 9m Maximum Range.
  • Ultra Wide 170° Detection Angle.
  • Latch & First To Alarm Inputs.
  • Digital Flex Detection For Improved False Alarm Immunity.
  • Glass Type Selection:Plate/Tempered/Laminated/Wired.
  • Adjustable Sensitivity.
  • Test Mode.
Click here to enquire
PREMIER-816

PREMIER 816

Features:
  • 8 Fully Programmable Zones(expandable to 16).
  • Integrated multi-protocol digital Communicator(pulse/express/fast Format, contact id, sia level II & Pager).
  • Local & remote upload/download Via wintex™ software.
  • 8 fully programmable outputs(2 supervised).
  • 2-wire/4-wire smoke detector.
  • Compatibility.
  • 4-wire data-bus for communicating with keypads & expanders.
  • 4 true partitions with separate Entry/Exit, bell delay & duration Timers.
  • Zone doubling feature.
  • 750 event log(time & date stamped).
  • 32 fully programmable access Codes.
  • 4 bypass groups.
  • Ctr21 telecommunication approval.
Click here to enquire
RE-–-900

Ravel 12 – 128 Zone Fire Alarm Panel

Model:RE – 900
Features:
  • Touch Keypad for user friendly operation.
  • Complies with UL-864 and NFPA-72.
  • Epoxy powder coated finish.
  • Operates on 110-220v 60/50 Hz, AC Mains power supply.
  • 12-128 Class 'B' Style ' B' or Style ' C' initiating device circuit(IDC).
  • Maximum current rating:5A for upto 24Zone & 10A for above 24 Zone.
  • 2 Nos of Class 'B' Notification Appliance Circuits(NAC).
  • NAC shall be programmed as auto silence/Silence Inhibit.
  • Standby(battery) backup 24v DC power supply with inbuilt Charger.
  • Error free Fire/Fault status in unambiguous colored LED indication.
  • 1000 Event storage with RTC.
  • Main, Standby status with audible and visual indication.
  • Three Programmable Form 'C' relays for fire and fault.
  • Resettable/Steady 24V D.C. Output.
  • RS485 Communication facility(Optional).
  • TCP/IP(Optional) facility.
  • One man Walk Test facility for Zone.
  • Zone Wise Sounder/Contact via RS485.
  • Password Enable/Disable facility for user level.
  • All field wiring circuits are Power limited except 110-220v AC and Battery.
  • All field wiring circuits are supervised except Relay contact.
  • Zone Isolation facility with loop voltage cut off.
  • Earth fault annunciation facility at 0 ohms.
  • Programmable AC loss delay.
  • Programmable Trouble reminder.
  • Peer to Peer Networkable maximum 16 Panels.