Products

Click here to enquire
Ravel-Avani

Ravel Avani Analogue Addressable Fire Alarm Control Panel

Features:
  • User friendly circuit.
  • Device/Detector wise configuration facility.
  • 2000 Event Storage with Real Time Clock.
  • Upto 192 grouping facility.
  • Pre Alarm Action.
  • All field wiring are power limited and supervised.
  • Programmable detector sensitivity.
  • Device type verification.
  • Earth fault annunciation facility at 0 ohms.
  • Double Address Sensing.
  • Walk test, Loop wise test, Lamp(LED) test.
  • 40 X 4 Characters LCD display.
  • Maximum 4 numbers of loop card with Class 'A', Style 5,6 or 7 and Class 'B' Style 4 wiring.
  • Maximum 254 devices(any combination) per loop.
  • Day/Night Mode facility.
  • USB 2.0 Interface for PC connectivity.
  • RS485 Communication facility for Network/Repeater.
  • Programmable Auto Silence Facility.
  • Programmable AC Loops Delay.
  • Programmable Silence Inhibit.
  • 2 no's of &#039 of programmable inputs.
  • Battery low audio, visual warning.
  • Three programmable Form 'C' relay for Fire, Fault and Supervisory.
  • 2 no's of &#039 of Supervise Notification Appliance Circuits.
Click here to enquire
RE-–-900

Ravel 12 – 128 Zone Fire Alarm Panel

Model:RE – 900
Features:
  • Touch Keypad for user friendly operation.
  • Complies with UL-864 and NFPA-72.
  • Epoxy powder coated finish.
  • Operates on 110-220v 60/50 Hz, AC Mains power supply.
  • 12-128 Class 'B' Style ' B' or Style ' C' initiating device circuit(IDC).
  • Maximum current rating:5A for upto 24Zone & 10A for above 24 Zone.
  • 2 Nos of Class 'B' Notification Appliance Circuits(NAC).
  • NAC shall be programmed as auto silence/Silence Inhibit.
  • Standby(battery) backup 24v DC power supply with inbuilt Charger.
  • Error free Fire/Fault status in unambiguous colored LED indication.
  • 1000 Event storage with RTC.
  • Main, Standby status with audible and visual indication.
  • Three Programmable Form 'C' relays for fire and fault.
  • Resettable/Steady 24V D.C. Output.
  • RS485 Communication facility(Optional).
  • TCP/IP(Optional) facility.
  • One man Walk Test facility for Zone.
  • Zone Wise Sounder/Contact via RS485.
  • Password Enable/Disable facility for user level.
  • All field wiring circuits are Power limited except 110-220v AC and Battery.
  • All field wiring circuits are supervised except Relay contact.
  • Zone Isolation facility with loop voltage cut off.
  • Earth fault annunciation facility at 0 ohms.
  • Programmable AC loss delay.
  • Programmable Trouble reminder.
  • Peer to Peer Networkable maximum 16 Panels.
Click here to enquire
PREMIER-LCDL

PREMIER LCDL

Features:
  • Large size LED keypad with multi levelback lighting.
  • Built in piezo sounder.
  • 2 programmable zone inputs.
  • 1 programmable output.
  • Speaker driver output.
Click here to enquire