PREMIER LCD
Features:
- LED keypad with multi levelback lighting.
- Built in piezo sounder.
- 2 programmable zone inputs.
- 1 programmable output.
Category: Fire Alarm.
Related Products
- Micro-Controller Based On Board Key Pad.
- Inbuilt speech dialer.
- Two Messages.
- 30 numbers.
- Two individual user codes-master and servant.
- User friendly circuit.
- Device/Detector wise configuration facility.
- 2000 Event Storage with Real Time Clock.
- Upto 192 grouping facility.
- Pre Alarm Action.
- All field wiring are power limited and supervised.
- Programmable detector sensitivity.
- Device type verification.
- Earth fault annunciation facility at 0 ohms.
- Double Address Sensing.
- Walk test, Loop wise test, Lamp(LED) test.
- 40 X 4 Characters LCD display.
- Maximum 4 numbers of loop card with Class 'A', Style 5,6 or 7 and Class 'B' Style 4 wiring.
- Maximum 254 devices(any combination) per loop.
- Day/Night Mode facility.
- USB 2.0 Interface for PC connectivity.
- RS485 Communication facility for Network/Repeater.
- Programmable Auto Silence Facility.
- Programmable AC Loops Delay.
- Programmable Silence Inhibit.
- 2 no's of ' of programmable inputs.
- Battery low audio, visual warning.
- Three programmable Form 'C' relay for Fire, Fault and Supervisory.
- 2 no's of ' of Supervise Notification Appliance Circuits.
- Touch Keypad for user friendly operation.
- Complies with UL-864 and NFPA-72.
- Epoxy powder coated finish.
- Operates on 110-220v 60/50 Hz, AC Mains power supply.
- 12-128 Class 'B' Style ' B' or Style ' C' initiating device circuit(IDC).
- Maximum current rating:5A for upto 24Zone & 10A for above 24 Zone.
- 2 Nos of Class 'B' Notification Appliance Circuits(NAC).
- NAC shall be programmed as auto silence/Silence Inhibit.
- Standby(battery) backup 24v DC power supply with inbuilt Charger.
- Error free Fire/Fault status in unambiguous colored LED indication.
- 1000 Event storage with RTC.
- Main, Standby status with audible and visual indication.
- Three Programmable Form 'C' relays for fire and fault.
- Resettable/Steady 24V D.C. Output.
- RS485 Communication facility(Optional).
- TCP/IP(Optional) facility.
- One man Walk Test facility for Zone.
- Zone Wise Sounder/Contact via RS485.
- Password Enable/Disable facility for user level.
- All field wiring circuits are Power limited except 110-220v AC and Battery.
- All field wiring circuits are supervised except Relay contact.
- Zone Isolation facility with loop voltage cut off.
- Earth fault annunciation facility at 0 ohms.
- Programmable AC loss delay.
- Programmable Trouble reminder.
- Peer to Peer Networkable maximum 16 Panels.
- Large size LED keypad with multi levelback lighting.
- Built in piezo sounder.
- 2 programmable zone inputs.
- 1 programmable output.
- Speaker driver output.
4 Zone Intrusion Burglar Intrusion Alarm Control Panel
Burglar alarm is a system designed to detect intrusion, unauthorized entry into a building or area.They are also called security alarms, security systems, alarm systems, intrusion detection systems, perimeter detection systems, and similar terms.
Premises Control Unit(PCU) or Panel:The “Brain” of the system, reads sensor inputs, tracks arm/disarm status and signals intrusions.In modern systems, this is typically one or more computer circuit boards inside a metal enclosure, along with a power supply.
Sensors:In devices which detect intrusions, Sensors may be placed at a perimeter of the protected area, within it, or both.Sensors can detect intruders by a variety of methods such as monitoring doors and windows for opening, by monitoring unoccupied interiors for motions, sound, vibration, or other disturbances.
Alerting Devices:These indicate an alarm condition, most commonly these are bells, sirens, and/or flashing lights.Alerting devices serve the dual purposes of warning occupants of intrusion, and potentially scaring off burglars.
Keypads:Small devices, typically wall-mounted, function as the human-machine interface to the system.In addition to buttons, keypads typically feature indicator lights, a small mulch-character display, or both.
Sensors:In devices which detect intrusions, Sensors may be placed at a perimeter of the protected area, within it, or both.Sensors can detect intruders by a variety of methods such as monitoring doors and windows for opening, by monitoring unoccupied interiors for motions, sound, vibration, or other disturbances.
Alerting Devices:These indicate an alarm condition, most commonly these are bells, sirens, and/or flashing lights.Alerting devices serve the dual purposes of warning occupants of intrusion, and potentially scaring off burglars.
Keypads:Small devices, typically wall-mounted, function as the human-machine interface to the system.In addition to buttons, keypads typically feature indicator lights, a small mulch-character display, or both.
Features:
Category: Fire Alarm.
Ravel Avani Analogue Addressable Fire Alarm Control Panel
Features:
Category: Fire Alarm.
Ravel 12 – 128 Zone Fire Alarm Panel
Model:RE – 900Features:
Category: Fire Alarm.
PREMIER LCDL
Features:
Category: Fire Alarm.